{"product_id":"cord-set-compl-47-49-57-for-tccs0185","title":"Cord Set Compl. (47-49\/57) For Tccs0185","description":"\u003c!-- Description --\u003e\r\n\u003ch3\u003eTork Craft Cord Set Compl. (47-49\/57) Service Kit (TCCS0185-SK11)\u003c\/h3\u003e\r\n\u003cp class=\"feature_box\"\u003e\u003cstrong\u003eAt a Glance: \u003c\/strong\u003eComplete replacement cord set (parts 47–49 and 57) for the Tork Craft TCCS0185 cut-off saw\u003c\/p\u003e\r\n\r\n\u003cp itemprop=\"description\"\u003e\r\nA cut-off saw cable gets dragged, tugged, kinked and occasionally “tested” against sharp edges and hot sparks. When the cord is damaged or internal connections become loose, you can get intermittent power, cutting out under load, tripping, or a very unsafe shock hazard. The Tork Craft TCCS0185-SK11 Cord Set Complete replaces the cord and related cord-set components referenced as parts 47 to 49, plus 57, helping restore safe cable support and dependable electrical supply to your TCCS0185.\r\n\u003c\/p\u003e\r\n\r\n\u003cdiv class=\"definition-products\"\u003e\r\n  \u003cstrong\u003eReliable power starts at the cable: renew the cord set the right way\u003c\/strong\u003e\r\n  \u003cp\u003e\r\n  Designed for the Tork Craft TCCS0185 platform, this kit is ideal for workshop repairs and preventative maintenance. A proper cord set replacement restores strain relief and secure connections, reducing repeat failures and improving day-to-day reliability.\r\n  \u003c\/p\u003e\r\n\u003c\/div\u003e\u003csection\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003c!-- Features and Benefits --\u003e\r\n\u003ch4\u003eFeatures\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eComplete cord-set replacement:\u003c\/strong\u003e Replaces the power cord and related cord-set components used in the TCCS0185 assembly.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eParts reference match:\u003c\/strong\u003e Covers parts \u003cstrong\u003e47–49 and 57\u003c\/strong\u003e as per the service diagram references.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImproves cable retention:\u003c\/strong\u003e Restores correct support to reduce internal wire fatigue and terminal stress.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eModel-specific compatibility:\u003c\/strong\u003e Intended for use with the \u003cstrong\u003eTork Craft TCCS0185\u003c\/strong\u003e cut-off saw.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eBenefits\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eSafer operation: \u003c\/strong\u003eReplacing damaged cords reduces the risk of electric shock, short circuits and overheating.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFix intermittent power issues: \u003c\/strong\u003eFresh wiring and proper support helps prevent cutting out when the cord is moved.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eLonger-lasting repair: \u003c\/strong\u003eCorrect strain relief and secure connections help prevent repeat failures.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003c!-- Specifications TAB --\u003e\r\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\r\n\u003ctable class=\"table SpecsTable\"\u003e\r\n  \u003cthead\u003e\r\n    \u003ctr\u003e\r\n      \u003cth class=\"SpecsSubHeading\"\u003eDescription\u003c\/th\u003e\r\n      \u003cth class=\"SpecsSubHeading\"\u003eSpec\u003c\/th\u003e\r\n    \u003c\/tr\u003e\r\n  \u003c\/thead\u003e\r\n  \u003ctbody\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eTork Craft\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eCat No.\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eTCCS0185-SK11\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eSpare Part Service Kit\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eComponent Group\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eCord Set Complete\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eParts Reference\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003e47–49 \u0026amp; 57\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eCompatible Tool Model\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eTCCS0185\u003c\/td\u003e\n\u003c\/tr\u003e\r\n  \u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eExtra Info\u003c\/h2\u003e\n\u003c!-- Extra Information TAB --\u003e\r\n\u003ch4\u003eExtra Information\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003eCompatibility: Intended for the \u003cstrong\u003eTork Craft TCCS0185\u003c\/strong\u003e cut-off saw series.\u003c\/li\u003e\r\n  \u003cli\u003eIf the saw trips a breaker, shocks, or smells of burning insulation, stop using it immediately and have it inspected by a qualified technician.\u003c\/li\u003e\r\n  \u003cli\u003eDuring replacement, inspect the switch terminals and internal wiring for heat damage or looseness.\u003c\/li\u003e\r\n  \u003cli\u003eEnsure the cord is routed correctly and secured so it cannot chafe against moving parts or sharp edges.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003c!-- Pro Tip --\u003e\r\n\u003cdiv class=\"tip-products\"\u003e\r\n  \u003ch4\u003ePro Tip\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003eBefore closing the housing, gently pull the cord from the outside while watching the internal connections — there should be \u003cstrong\u003eno movement\u003c\/strong\u003e at the terminals. Finish with a short \u003cstrong\u003eno-load test\u003c\/strong\u003e and confirm stable power before cutting.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\r\n\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSafety\u003c\/h2\u003e\n\u003c!-- Safety TAB --\u003e\r\n\u003ch4\u003eSafety\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003eWear \u003cstrong\u003eeye protection\u003c\/strong\u003e and a \u003cstrong\u003edust mask\u003c\/strong\u003e when opening housings and cleaning internal dust.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eDisconnect power\u003c\/strong\u003e before opening the tool or fitting any electrical spare parts.\u003c\/li\u003e\r\n  \u003cli\u003eDamaged cords are a shock hazard — never tape over severe insulation damage; replace correctly.\u003c\/li\u003e\r\n  \u003cli\u003eElectrical repairs should be completed by a competent technician; incorrect wiring can cause \u003cstrong\u003eelectric shock\u003c\/strong\u003e or fire.\u003c\/li\u003e\r\n  \u003cli\u003eAfter repair, perform a brief \u003cstrong\u003eno-load test\u003c\/strong\u003e in a safe area and stop immediately if you smell burning, see arcing or the tool behaves erratically.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e","brand":"Saddle Creek","offers":[{"title":"Default Title","offer_id":67530356228386,"sku":"TCCS0185-SK11","price":268.53,"currency_code":"ZAR","in_stock":false}],"url":"https:\/\/saddlecreek.co.za\/products\/cord-set-compl-47-49-57-for-tccs0185","provider":"Saddle Creek","version":"1.0","type":"link"}