{"product_id":"fixman-1000v-cat-ii-digital-multimeter","title":"Fixman 1000V CAT II Digital Multimeter","description":"\u003c!-- Description --\u003e\r\n\u003ch3\u003eFixman 1000V CAT II Digital Multimeter\u003c\/h3\u003e\r\n\u003cp class=\"feature_box\"\u003e\u003cstrong\u003eAt a Glance: \u003c\/strong\u003eManual-ranging digital multimeter for AC\/DC voltage, DC current, resistance, diode, transistor and battery testing\u003c\/p\u003e\r\n\u003cp itemprop=\"description\"\u003eThe Fixman Digital Multimeter is a versatile electrical testing instrument designed for fault finding, maintenance and general electrical diagnostics. Its clearly marked rotary function and range selector provides access to DC voltage measurement up to 1000V, AC voltage measurement up to 750V, DC current measurement up to 10A and resistance measurement up to 2000kΩ. Additional non-contact voltage detection, diode testing, transistor testing and battery-test functions make it a practical companion for technicians, electricians, automotive users and DIY enthusiasts.\u003c\/p\u003e\r\n\r\n\u003cdiv class=\"definition-products\"\u003e\n\u003cstrong\u003eMultiple electrical testing functions in one compact instrument\u003c\/strong\u003e\r\n  \u003cp\u003eFrom checking batteries and tracing basic electrical faults to measuring voltage, current and resistance, this manual-ranging multimeter combines essential diagnostic functions in one easy-to-use handheld unit.\u003c\/p\u003e\r\n\u003c\/div\u003e\r\n\r\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eAC and DC voltage measurement:\u003c\/strong\u003e Measures DC voltage up to 1000V and AC voltage up to 750V.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eDC current measurement:\u003c\/strong\u003e Provides ranges from 200µA through to 10A for compatible circuits.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eResistance measurement:\u003c\/strong\u003e Measures resistance across five selectable ranges up to 2000kΩ.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-contact voltage detection:\u003c\/strong\u003e The NCV function helps identify the possible presence of AC voltage without direct conductor contact.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eDiode test:\u003c\/strong\u003e Assists with checking the condition and forward-voltage behaviour of compatible diodes.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eTransistor test:\u003c\/strong\u003e Includes an hFE function for basic compatible transistor testing.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBattery testing:\u003c\/strong\u003e Dedicated 1.5V and 9V battery-test positions support convenient battery checks.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eManual range selection:\u003c\/strong\u003e The rotary selector allows the user to choose the required function and measurement range.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAT II rated:\u003c\/strong\u003e Marked CAT II for measurements within the applicable category and voltage limits.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003csection\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003c!-- Features and Benefits --\u003e\r\n\u003ch4\u003eFeatures\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eDigital display:\u003c\/strong\u003e Presents measurement results in an easy-to-read numerical format.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eRotary function and range switch:\u003c\/strong\u003e Provides direct selection of voltage, current, resistance and component-test functions.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eDedicated input terminals:\u003c\/strong\u003e Includes COM, VΩmA and 10A input terminals for the applicable test-lead configuration.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eProtected VΩmA input:\u003c\/strong\u003e The input is marked with fused protection and specified electrical limits.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCompact handheld design:\u003c\/strong\u003e Convenient for storage in a toolbox and use during maintenance or diagnostic work.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eMultiple diagnostic modes:\u003c\/strong\u003e Combines electrical measurement, NCV detection, diode testing, transistor testing and battery testing.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eBenefits\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eVersatile fault finding: \u003c\/strong\u003eOne instrument covers many common electrical and electronic testing requirements.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eWide measurement coverage: \u003c\/strong\u003eMultiple selectable ranges accommodate small electronic readings and higher-voltage applications within the instrument's rating.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eConvenient circuit checks: \u003c\/strong\u003eMeasure voltage, DC current and resistance without carrying separate instruments.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eUseful component testing: \u003c\/strong\u003eDiode and transistor functions support basic electronic troubleshooting.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eQuick battery checks: \u003c\/strong\u003eDedicated 1.5V and 9V positions make testing common batteries more convenient.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eGreater measurement control: \u003c\/strong\u003eManual range selection allows the user to choose a range suited to the expected value.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication\u003c\/h4\u003e\r\n\u003cul class=\"sideline-bullet\"\u003e\r\n  \u003cli\u003eGeneral electrical fault finding.\u003c\/li\u003e\r\n  \u003cli\u003eAutomotive and low-voltage electrical diagnostics.\u003c\/li\u003e\r\n  \u003cli\u003eBattery voltage and condition checks.\u003c\/li\u003e\r\n  \u003cli\u003eTesting compatible household electrical circuits.\u003c\/li\u003e\r\n  \u003cli\u003eElectronic component testing.\u003c\/li\u003e\r\n  \u003cli\u003eMeasuring resistance in isolated components and circuits.\u003c\/li\u003e\r\n  \u003cli\u003eChecking compatible DC current loads.\u003c\/li\u003e\r\n  \u003cli\u003eWorkshop, maintenance and DIY electrical work.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003c!-- Specifications TAB --\u003e\r\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\r\n\u003ctable class=\"table SpecsTable\"\u003e\r\n  \u003cthead\u003e\r\n    \u003ctr\u003e\r\n      \u003cth class=\"SpecsSubHeading\"\u003eDescription\u003c\/th\u003e\r\n      \u003cth class=\"SpecsSubHeading\"\u003eSpec\u003c\/th\u003e\r\n    \u003c\/tr\u003e\r\n  \u003c\/thead\u003e\r\n  \u003ctbody\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eBrand\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eFixman\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eCat No.\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eFIX Y1001\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eManufacturer Model\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eY1001\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eProduct Type\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eDigital Multimeter\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eRange Selection\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eManual\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eSafety Category\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eCAT II\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eMaximum DC Voltage\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e1000V DC\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eDC Voltage Ranges\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e200mV, 2000mV, 20V, 200V and 1000V\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eMaximum AC Voltage\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e750V AC\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eAC Voltage Ranges\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e200V and 750V\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eDC Current Ranges\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e200µA, 2000µA, 20mA, 200mA and 10A\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eResistance Ranges\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e200Ω, 2000Ω, 20kΩ, 200kΩ and 2000kΩ\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eBattery Test\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e1.5V and 9V\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eNon-Contact Voltage Detection\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eYes\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eDiode Test\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eYes\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eTransistor Test\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003ehFE\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eInput Terminals\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eCOM, VΩmA and 10A\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eOperating Temperature\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e0°C to 40°C, Relative Humidity Below 75%\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eStorage Temperature\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e-10°C to 50°C, Relative Humidity Below 85%\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n  \u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\r\n\u003ch3\u003eIn the box:\u003c\/h3\u003e\r\n\u003cul class=\"sideline-bullet\"\u003e\r\n  \u003cli\u003e1 x Fixman Y1001 Digital Multimeter\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eExtra Info\u003c\/h2\u003e\n\u003c!-- Extra Information TAB --\u003e\r\n\u003ch4\u003eExtra Information\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003eThis is a manual-ranging multimeter; select a range higher than the expected value before taking a measurement.\u003c\/li\u003e\r\n  \u003cli\u003eUse the COM and VΩmA terminals for voltage, resistance, diode and low-current measurements within the marked input limits.\u003c\/li\u003e\r\n  \u003cli\u003eUse the dedicated 10A terminal only when measuring current on the 10A range.\u003c\/li\u003e\r\n  \u003cli\u003eResistance, diode and transistor testing must only be performed on de-energised circuits or disconnected components.\u003c\/li\u003e\r\n  \u003cli\u003eThe NCV function is an indication aid and should not be treated as definitive proof that a circuit is safe to touch.\u003c\/li\u003e\r\n  \u003cli\u003eCAT II applies to measurements on suitable circuits directly connected to low-voltage installations, such as appliances and portable equipment, within the meter's marked limits.\u003c\/li\u003e\r\n  \u003cli\u003eAlways inspect the multimeter and test leads before use and follow the operating instructions.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003c!-- Pro Tip --\u003e\r\n\u003cdiv class=\"tip-products\"\u003e\r\n  \u003ch4\u003ePro Tips\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003eIf the expected voltage or current is unknown, begin with the highest suitable range and work downward for a clearer reading.\u003c\/li\u003e\r\n    \u003cli\u003eCheck the test-lead positions before every measurement, especially after using the 10A current terminal.\u003c\/li\u003e\r\n    \u003cli\u003eMeasure voltage in parallel with the circuit and current in series with the load.\u003c\/li\u003e\r\n    \u003cli\u003eFor resistance testing, isolate the component and discharge any capacitors before connecting the probes.\u003c\/li\u003e\r\n    \u003cli\u003eTouch the test probes together before resistance testing to confirm that the leads and meter respond correctly.\u003c\/li\u003e\r\n    \u003cli\u003eUse the NCV function as an initial screening tool, then verify circuit status using an appropriate contact measurement.\u003c\/li\u003e\r\n    \u003cli\u003eTurn the rotary selector to OFF when the multimeter is not in use to help preserve the battery.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\r\n\u003c\/div\u003e\r\n\r\n\u003c!-- How to use --\u003e\r\n\u003cdiv class=\"product-instructions\"\u003e\r\n  \u003ch3\u003eHow to Use\u003c\/h3\u003e\r\n  \u003cul class=\"numbered-list\"\u003e\r\n    \u003cli\u003eInspect the multimeter, test leads, probes and input terminals for damage before use.\u003c\/li\u003e\r\n    \u003cli\u003eConnect the black test lead to the COM terminal.\u003c\/li\u003e\r\n    \u003cli\u003eConnect the red test lead to the VΩmA terminal, or to the 10A terminal only when the 10A current range is required.\u003c\/li\u003e\r\n    \u003cli\u003eTurn the rotary selector to the required measurement function and begin with a range above the expected value.\u003c\/li\u003e\r\n    \u003cli\u003eConnect the probes correctly to the circuit: in parallel for voltage or resistance and in series for current.\u003c\/li\u003e\r\n    \u003cli\u003eRead the measured value on the digital display and select a lower range if improved resolution is required.\u003c\/li\u003e\r\n    \u003cli\u003eDisconnect the probes from the circuit before changing between incompatible functions or moving the red lead between input terminals.\u003c\/li\u003e\r\n    \u003cli\u003eTurn the selector to OFF after use and store the multimeter and test leads safely.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\r\n\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSafety\u003c\/h2\u003e\n\u003c!-- Safety TAB --\u003e\r\n\u003ch4\u003eSafety\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003eWear appropriate \u003cstrong\u003eeye protection and electrically rated personal protective equipment\u003c\/strong\u003e for the circuit and working environment.\u003c\/li\u003e\r\n  \u003cli\u003eRead and understand the operating instructions before using the multimeter.\u003c\/li\u003e\r\n  \u003cli\u003eNever exceed the voltage, current, measurement-category or terminal limits marked on the instrument.\u003c\/li\u003e\r\n  \u003cli\u003eDo not use the multimeter if its casing, display, input terminals, probes or test leads are damaged.\u003c\/li\u003e\r\n  \u003cli\u003eKeep fingers behind the protective guards on the test probes during measurements.\u003c\/li\u003e\r\n  \u003cli\u003eNever measure voltage while the red lead is connected to the 10A current terminal.\u003c\/li\u003e\r\n  \u003cli\u003eDisconnect circuit power before measuring resistance or testing diodes and transistors.\u003c\/li\u003e\r\n  \u003cli\u003eDischarge capacitors and confirm that stored energy has been removed before resistance or component testing.\u003c\/li\u003e\r\n  \u003cli\u003eDo not change functions, ranges or terminal connections while the probes remain connected to a hazardous live circuit.\u003c\/li\u003e\r\n  \u003cli\u003eNCV detection is an indication only; verify that a circuit is de-energised using an appropriate contact test before touching conductors.\u003c\/li\u003e\r\n  \u003cli\u003eDo not use this CAT II meter on circuits or installations requiring a higher measurement category.\u003c\/li\u003e\r\n  \u003cli\u003eIf you are not trained to work safely on electrical systems, have the testing performed by a qualified electrician.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e","brand":"Saddle Creek","offers":[{"title":"Default Title","offer_id":67521492779298,"sku":"FIX Y1001","price":358.8,"currency_code":"ZAR","in_stock":false}],"url":"https:\/\/saddlecreek.co.za\/products\/fixman-1000v-cat-ii-digital-multimeter","provider":"Saddle Creek","version":"1.0","type":"link"}