{"product_id":"fixman-600v-cat-iii-digital-multimeter","title":"Fixman 600V CAT III Digital Multimeter","description":"\u003c!-- Description --\u003e\r\n\u003ch3\u003eFixman 600V CAT III Digital Multimeter\u003c\/h3\u003e\r\n\u003cp class=\"feature_box\"\u003e\u003cstrong\u003eAt a Glance: \u003c\/strong\u003e2000-count manual-ranging multimeter with a backlit LCD, data hold and 600V CAT III rating\u003c\/p\u003e\r\n\u003cp itemprop=\"description\"\u003eThe Fixman 600V CAT III Digital Multimeter is a compact and capable instrument for electrical testing, fault finding and routine maintenance. It measures AC and DC voltage up to 600V, DC current up to 10A and resistance up to 20MΩ, while also providing continuity and diode-test functions. A clear 2000-count LCD, selectable backlight and data-hold function make readings easier to capture in workshops, electrical panels and poorly illuminated working areas.\u003c\/p\u003e\r\n\r\n\u003cdiv class=\"definition-products\"\u003e\n\u003cstrong\u003eClear, controlled electrical testing for everyday diagnostics\u003c\/strong\u003e\r\n  \u003cp\u003eThe manual-ranging selector gives the user direct control over the measurement function and range. Combined with three clearly identified input terminals, a protective outer housing and a CAT III 600V rating, it is a practical choice for qualified users performing compatible electrical and electronic tests.\u003c\/p\u003e\r\n\u003c\/div\u003e\r\n\r\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCAT III 600V rating:\u003c\/strong\u003e Designed for compatible measurements within its marked voltage and measurement-category limits.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003e2000-count LCD:\u003c\/strong\u003e Provides a clear digital display for convenient measurement reading.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eAC and DC voltage measurement:\u003c\/strong\u003e Measures both AC and DC voltage up to 600V.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eDC current measurement:\u003c\/strong\u003e Measures compatible DC current from 0.01mA up to 10A.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eResistance measurement:\u003c\/strong\u003e Covers resistance values from 0.1Ω up to 20MΩ.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eContinuity test:\u003c\/strong\u003e Assists with identifying complete circuits, conductors and electrical connections.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eDiode test:\u003c\/strong\u003e Supports basic checking of compatible diodes and semiconductor junctions.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eData hold:\u003c\/strong\u003e Freezes the displayed reading for convenient recording or viewing.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eDisplay backlight:\u003c\/strong\u003e Improves display visibility in dimly lit working areas.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003csection\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003c!-- Features and Benefits --\u003e\r\n\u003ch4\u003eFeatures\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eManual range selection:\u003c\/strong\u003e The rotary selector provides direct control of the required function and measuring range.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eThree input terminals:\u003c\/strong\u003e Includes COM, VΩmA and dedicated 10A connections.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eProtective outer housing:\u003c\/strong\u003e The shaped casing helps improve grip and protect the instrument during normal use.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBacklight and hold button:\u003c\/strong\u003e Provides quick access to the display-lighting and data-hold functions.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBattery powered:\u003c\/strong\u003e Operates using two 1.5V AAA batteries.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCompact handheld format:\u003c\/strong\u003e Convenient for toolbox storage, maintenance calls and workshop diagnostics.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eBenefits\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eVersatile fault finding: \u003c\/strong\u003eMeasures the principal electrical values required for many common diagnostic tasks.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImproved visibility: \u003c\/strong\u003eThe backlit LCD makes readings easier to view in poorly illuminated areas.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eConvenient reading capture: \u003c\/strong\u003eData hold keeps a measurement on the display after the probes are removed.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eUseful circuit checking: \u003c\/strong\u003eContinuity and diode-test modes support wiring and component diagnostics.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eControlled measurement selection: \u003c\/strong\u003eManual ranges allow the user to select a range suited to the expected value.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003ePortable operation: \u003c\/strong\u003eAAA battery power allows the multimeter to be used wherever compatible testing is required.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eApplication\u003c\/h4\u003e\r\n\u003cul class=\"sideline-bullet\"\u003e\r\n  \u003cli\u003eGeneral electrical fault finding.\u003c\/li\u003e\r\n  \u003cli\u003eTesting AC and DC voltage.\u003c\/li\u003e\r\n  \u003cli\u003eMeasuring compatible DC current.\u003c\/li\u003e\r\n  \u003cli\u003eResistance measurement on isolated circuits and components.\u003c\/li\u003e\r\n  \u003cli\u003eChecking wires, fuses and electrical connections for continuity.\u003c\/li\u003e\r\n  \u003cli\u003eBasic diode testing.\u003c\/li\u003e\r\n  \u003cli\u003eAutomotive and low-voltage electrical diagnostics.\u003c\/li\u003e\r\n  \u003cli\u003eWorkshop, maintenance and qualified DIY electrical work.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003c!-- Specifications TAB --\u003e\r\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\r\n\u003ctable class=\"table SpecsTable\"\u003e\r\n  \u003cthead\u003e\r\n    \u003ctr\u003e\r\n      \u003cth class=\"SpecsSubHeading\"\u003eDescription\u003c\/th\u003e\r\n      \u003cth class=\"SpecsSubHeading\"\u003eSpec\u003c\/th\u003e\r\n    \u003c\/tr\u003e\r\n  \u003c\/thead\u003e\r\n  \u003ctbody\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eBrand\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eFixman\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eCat No.\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eFIX Y1009\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eManufacturer Model\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eY1009\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eProduct Type\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eDigital Multimeter\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eRange Selection\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eManual\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eDisplay\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eLCD\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eDisplay Count\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e2000 Counts\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eDisplay Backlight\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eYes\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eData Hold\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eYes\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eSafety Category\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eCAT III 600V\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eDC Voltage Range\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e0.1mV–600V\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eAC Voltage Range\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e0.01V–600V\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eDC Current Range\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e0.01mA–10A\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eResistance Range\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e0.1Ω–20MΩ\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eContinuity Test\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eYes\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eDiode Test\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eYes\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eInput Terminals\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eCOM, VΩmA and 10A\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003ePower Supply\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e2 x 1.5V AAA Batteries\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eOperating Environment\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e0°C to 40°C, Maximum 80% Relative Humidity\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eOperating Location\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003eIndoor Use, Altitude Below 2000m\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n    \u003ctr\u003e\r\n      \u003ctd class=\"SpecLeft\"\u003eStorage Environment\u003c\/td\u003e\r\n      \u003ctd class=\"SpecRight\"\u003e-10°C to 60°C, Maximum 80% Relative Humidity, Batteries Removed\u003c\/td\u003e\r\n    \u003c\/tr\u003e\r\n  \u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\r\n\u003ch3\u003eIn the box:\u003c\/h3\u003e\r\n\u003cul class=\"sideline-bullet\"\u003e\r\n  \u003cli\u003e1 x Fixman Y1009 Digital Multimeter\u003c\/li\u003e\r\n  \u003cli\u003e1 x Pair of Test Leads\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eExtra Info\u003c\/h2\u003e\n\u003c!-- Extra Information TAB --\u003e\r\n\u003ch4\u003eExtra Information\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003eThis is a manual-ranging multimeter; select a range higher than the expected measurement before testing.\u003c\/li\u003e\r\n  \u003cli\u003eUse the COM and VΩmA terminals for voltage, resistance, continuity, diode and applicable low-current measurements.\u003c\/li\u003e\r\n  \u003cli\u003eUse the dedicated 10A terminal only when measuring current with the appropriate 10A range selected.\u003c\/li\u003e\r\n  \u003cli\u003eVoltage is measured with the multimeter connected in parallel, while current is measured with the meter connected in series.\u003c\/li\u003e\r\n  \u003cli\u003eResistance, continuity and diode testing must only be performed on de-energised circuits or disconnected components.\u003c\/li\u003e\r\n  \u003cli\u003eThe CAT III 600V marking applies only when the meter is used correctly with suitably rated test leads and within all marked limits.\u003c\/li\u003e\r\n  \u003cli\u003eThe instrument is specified for indoor operation at altitudes below 2000m.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003c!-- Pro Tip --\u003e\r\n\u003cdiv class=\"tip-products\"\u003e\r\n  \u003ch4\u003ePro Tips\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003eIf the expected value is unknown, begin with the highest suitable range and work downward for improved resolution.\u003c\/li\u003e\r\n    \u003cli\u003eCheck the red test-lead position before every measurement, especially after using the 10A input.\u003c\/li\u003e\r\n    \u003cli\u003eUse the data-hold function when the display cannot be viewed safely while the probes are connected.\u003c\/li\u003e\r\n    \u003cli\u003eTurn on the backlight only when needed to help extend battery life.\u003c\/li\u003e\r\n    \u003cli\u003eTouch the probes together before a continuity test to confirm that the test leads and meter respond correctly.\u003c\/li\u003e\r\n    \u003cli\u003eFor resistance and diode testing, isolate the component and discharge all capacitors before connecting the probes.\u003c\/li\u003e\r\n    \u003cli\u003eTurn the selector to OFF after use and remove the batteries before prolonged storage.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\r\n\u003c\/div\u003e\r\n\r\n\u003c!-- How to use --\u003e\r\n\u003cdiv class=\"product-instructions\"\u003e\r\n  \u003ch3\u003eHow to Use\u003c\/h3\u003e\r\n  \u003cul class=\"numbered-list\"\u003e\r\n    \u003cli\u003eInspect the multimeter, input terminals, test leads and probe insulation for damage before use.\u003c\/li\u003e\r\n    \u003cli\u003eConnect the black test lead to the COM input terminal.\u003c\/li\u003e\r\n    \u003cli\u003eConnect the red test lead to the VΩmA terminal, or to the 10A terminal only when the applicable high-current range is required.\u003c\/li\u003e\r\n    \u003cli\u003eTurn the rotary selector to the required function and begin with a range above the expected measurement.\u003c\/li\u003e\r\n    \u003cli\u003eConnect the probes correctly to the circuit: in parallel for voltage and resistance, or in series for current.\u003c\/li\u003e\r\n    \u003cli\u003eRead the result on the LCD and select a lower range if improved resolution is required.\u003c\/li\u003e\r\n    \u003cli\u003eUse the hold function when necessary to retain the reading, and the backlight when additional display illumination is needed.\u003c\/li\u003e\r\n    \u003cli\u003eDisconnect the probes before changing between incompatible functions or moving the red lead between input terminals.\u003c\/li\u003e\r\n    \u003cli\u003eTurn the selector to OFF after testing and store the instrument and test leads safely.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\r\n\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSafety\u003c\/h2\u003e\n\u003c!-- Safety TAB --\u003e\r\n\u003ch4\u003eSafety\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003eWear appropriate \u003cstrong\u003eeye protection and electrically rated personal protective equipment\u003c\/strong\u003e for the circuit and working environment.\u003c\/li\u003e\r\n  \u003cli\u003eRead and understand the operating instructions before using the multimeter.\u003c\/li\u003e\r\n  \u003cli\u003eNever exceed the 600V rating, measurement category or terminal limits marked on the instrument.\u003c\/li\u003e\r\n  \u003cli\u003eDo not use the multimeter if its casing, display, input terminals, probes or test leads are damaged.\u003c\/li\u003e\r\n  \u003cli\u003eKeep fingers behind the protective guards on the test probes during measurements.\u003c\/li\u003e\r\n  \u003cli\u003eNever measure voltage while the red test lead is connected to the 10A input terminal.\u003c\/li\u003e\r\n  \u003cli\u003eDisconnect circuit power before measuring resistance, checking continuity or testing diodes.\u003c\/li\u003e\r\n  \u003cli\u003eDischarge capacitors and confirm that stored electrical energy has been removed before testing.\u003c\/li\u003e\r\n  \u003cli\u003eDo not change functions, ranges or test-lead terminal positions while connected to a hazardous live circuit.\u003c\/li\u003e\r\n  \u003cli\u003eDo not use this CAT III meter on circuits requiring a higher measurement category or voltage rating.\u003c\/li\u003e\r\n  \u003cli\u003eReplace internal protection components only with components of the specified type and rating.\u003c\/li\u003e\r\n  \u003cli\u003eIf you are not trained to work safely on electrical systems, have the testing performed by a qualified electrician.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e","brand":"Saddle Creek","offers":[{"title":"Default Title","offer_id":67521496842530,"sku":"FIX Y1009","price":436.43,"currency_code":"ZAR","in_stock":false}],"url":"https:\/\/saddlecreek.co.za\/products\/fixman-600v-cat-iii-digital-multimeter","provider":"Saddle Creek","version":"1.0","type":"link"}