{"product_id":"non-return-valve-for-sg-comp06-07","title":"Non Return Valve For Sg Comp06\/07","description":"\u003c!-- Description --\u003e\r\n\u003ch3\u003eAirCraft Non-Return Valve For SG COMP06 \u0026amp; SG COMP07 (SG COMP06-03)\u003c\/h3\u003e\r\n\u003cp class=\"feature_box\"\u003e\u003cstrong\u003eAt a Glance: \u003c\/strong\u003eCompressor non-return (check) valve—prevents backflow and helps keep tank pressure stable.\u003c\/p\u003e\r\n\r\n\u003cp itemprop=\"description\"\u003e\r\nA non-return valve (also called a check valve) is a small part with a big job: it allows air to flow into the tank, but stops it from flowing back toward the compressor head. The AirCraft SG COMP06-03 Non-Return Valve is designed for the SG COMP06 and SG COMP07 compressor range. If a compressor struggles to restart under pressure, leaks air back through the line, or loses tank pressure faster than expected, a worn check valve is often the culprit. Replacing the non-return valve helps maintain stored pressure, supports smoother cycling, and protects the compressor mechanism from backflow stress.\r\n\u003c\/p\u003e\r\n\r\n\u003cdiv class=\"definition-products\"\u003e\r\n  \u003cstrong\u003eStop The Backflow: a check valve that helps your compressor hold pressure and restart reliably\u003c\/strong\u003e\r\n  \u003cp\u003e\r\n  Check valves keep tank pressure where it belongs—inside the tank. When they fail, air can bleed back, forcing the compressor to fight against pressure during start-up and reducing overall efficiency.\r\n  \u003c\/p\u003e\r\n\u003c\/div\u003e\u003csection\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003c!-- Features and Benefits --\u003e\r\n\u003ch4\u003eFeatures\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eNon-return (check) valve\u003c\/strong\u003e Allows one-way airflow into the tank and blocks backflow\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eDesigned for SG COMP06 \u0026amp; SG COMP07\u003c\/strong\u003e Correct spare part fitment for compatible compressors\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eSupports pressure retention\u003c\/strong\u003e Helps maintain tank pressure and efficient compressor cycling\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eService-friendly spare\u003c\/strong\u003e Ideal for maintenance and fixing common leak\/backflow issues\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eBenefits\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eImproved start-up: \u003c\/strong\u003eHelps prevent the compressor from starting against back pressure\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eBetter pressure stability: \u003c\/strong\u003eReduces pressure loss from backflow through the line\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eProtects the compressor: \u003c\/strong\u003eHelps reduce stress on the pump mechanism and seals\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eCost-effective repair: \u003c\/strong\u003eFix a common fault without replacing the whole compressor\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003c!-- Specifications TAB --\u003e\r\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\r\n\u003ctable class=\"table SpecsTable\"\u003e\r\n  \u003cthead\u003e\r\n    \u003ctr\u003e\r\n      \u003cth class=\"SpecsSubHeading\"\u003eDescription\u003c\/th\u003e\r\n      \u003cth class=\"SpecsSubHeading\"\u003eSpec\u003c\/th\u003e\r\n    \u003c\/tr\u003e\r\n  \u003c\/thead\u003e\r\n  \u003ctbody\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eAirCraft\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eCat No.\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eSG COMP06-03\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eNon-Return Valve \/ Check Valve (Spare Part)\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eCompatible Models\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eAirCraft SG COMP06 \/ SG COMP07\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eFunction\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eOne-Way Airflow, Backflow Prevention, Pressure Retention\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eApplication\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eCompressor Maintenance, Leak Repair, Start-Up Improvement\u003c\/td\u003e\n\u003c\/tr\u003e\r\n  \u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eExtra Info\u003c\/h2\u003e\n\u003c!-- Extra Information TAB --\u003e\r\n\u003ch4\u003eExtra Information\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003eCommon symptoms of a failing check valve include hissing\/leaking near the tank line and difficulty restarting when the tank is pressurised.\u003c\/li\u003e\r\n  \u003cli\u003eCheck fittings and thread seals during installation—small leaks can mimic valve failure.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003c!-- Pro Tip --\u003e\r\n\u003cdiv class=\"tip-products\"\u003e\r\n  \u003ch4\u003ePro Tip\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003eBefore removing the valve, switch off and unplug the compressor, then fully release tank pressure. Working on pressurised fittings is a fast way to turn a small job into a loud one.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\r\n\u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSafety\u003c\/h2\u003e\n\u003c!-- Safety TAB --\u003e\r\n\u003ch4\u003eSafety\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003eSwitch off, unplug and \u003cstrong\u003erelease all tank pressure\u003c\/strong\u003e before removing fittings or valves.\u003c\/li\u003e\r\n  \u003cli\u003eWear \u003cstrong\u003eeye protection\u003c\/strong\u003e when working on pressurised systems and small fittings.\u003c\/li\u003e\r\n  \u003cli\u003eEnsure all connections are secure before re-pressurising the system.\u003c\/li\u003e\r\n  \u003cli\u003eAfter installation, perform a leak check using soapy water around the fitting area.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e","brand":"Saddle Creek","offers":[{"title":"Default Title","offer_id":67500871385378,"sku":"SG COMP06-03","price":108.33,"currency_code":"ZAR","in_stock":false}],"url":"https:\/\/saddlecreek.co.za\/products\/non-return-valve-for-sg-comp06-07","provider":"Saddle Creek","version":"1.0","type":"link"}