{"product_id":"preassure-switch","title":"Preassure Switch","description":"\u003c!-- Description --\u003e\r\n  \u003ch3\u003eAirCraft Pressure Switch SG-COMP06-31\u003c\/h3\u003e\r\n  \u003cp class=\"feature_box\"\u003e\u003cstrong\u003eAt a Glance: \u003c\/strong\u003ePre-wired pressure switch with threaded connection for automatic compressor start\/stop control.\u003c\/p\u003e\r\n  \u003cp itemprop=\"description\"\u003e\r\n    The AirCraft \u003cstrong\u003eSG-COMP06-31 Pressure Switch\u003c\/strong\u003e is the “brain stem” of many compressor setups—monitoring pressure and telling the compressor when to switch on and off. \r\n    When pressure drops to the cut-in point, it allows the compressor to start building pressure again; when the tank\/system reaches the cut-out point, it switches off to help prevent over-pressurising.\r\n    If your compressor is not starting, not stopping, cycling erratically, or struggling to maintain stable operation, a worn or faulty pressure switch is a common culprit. This AirCraft spare part is a practical replacement to restore dependable automatic control on compatible units.\r\n  \u003c\/p\u003e\r\n\r\n  \u003cdiv class=\"definition-products\"\u003e\r\n    \u003cstrong\u003eAutomatic Pressure Control You Can Trust: the SG-COMP06-31 Pressure Switch\u003c\/strong\u003e\r\n    \u003cp\u003e\r\n      Designed for compressor applications where reliable cut-in\/cut-out control is essential for safety and performance.\r\n      Match the \u003cstrong\u003eCat No. SG-COMP06-31\u003c\/strong\u003e to your existing switch to ensure correct fitment and function.\r\n    \u003c\/p\u003e\r\n  \u003c\/div\u003e\u003csection\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e  \u003c!-- Features and Benefits --\u003e\r\n  \u003ch4\u003eFeatures\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eAutomatic cut-in \/ cut-out control\u003c\/strong\u003e Helps manage compressor cycling based on system pressure.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eThreaded pressure port\u003c\/strong\u003e Designed to mount into the appropriate pressure connection point.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003ePre-wired leads\u003c\/strong\u003e Simplifies installation and keeps wiring neat in the control area.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eCompact, service-friendly design\u003c\/strong\u003e Ideal for maintenance and straightforward replacement by part number.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\r\n\r\n  \u003ch4\u003eBenefits\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eImproves safety: \u003c\/strong\u003eHelps prevent over-pressurising by switching off at the correct point.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eRestores reliable operation: \u003c\/strong\u003eFixes common issues like failing to start\/stop or unstable cycling.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eProtects the compressor: \u003c\/strong\u003eMore consistent switching can reduce strain and unnecessary wear.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eBetter efficiency: \u003c\/strong\u003eHelps the compressor run only when needed to maintain pressure.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e  \u003c!-- Specifications TAB --\u003e\r\n  \u003ch4\u003eSpecifications\u003c\/h4\u003e\r\n  \u003ctable class=\"table SpecsTable\"\u003e\r\n    \u003cthead\u003e\r\n      \u003ctr\u003e\r\n        \u003cth class=\"SpecsSubHeading\"\u003eDescription\u003c\/th\u003e\r\n        \u003cth class=\"SpecsSubHeading\"\u003eSpec\u003c\/th\u003e\r\n      \u003c\/tr\u003e\r\n    \u003c\/thead\u003e\r\n    \u003ctbody\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eAirCraft\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eCat No.\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eSG-COMP06-31\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003ePressure Switch (Spare Part)\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eFunction\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eAutomatic compressor start\/stop control (cut-in \/ cut-out)\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eThreaded pressure port (confirm size to existing unit)\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eWiring\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003ePre-wired leads (as pictured)\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eApplication\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eCompatible AirCraft compressor assembly (model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eReplacement Use\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eDirect replacement by part number\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003c\/tbody\u003e\r\n  \u003c\/table\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eExtra Info\u003c\/h2\u003e\r\n  \u003c!-- Extra Information TAB --\u003e\r\n  \u003ch4\u003eExtra Information\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eConfirm compatibility:\u003c\/strong\u003e Match \u003cstrong\u003eSG-COMP06-31\u003c\/strong\u003e with your existing part and compressor model.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eCheck pressure ratings:\u003c\/strong\u003e Ensure the switch is suitable for your system’s operating pressure range.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eVerify wiring:\u003c\/strong\u003e Confirm correct wire connections and insulation before powering up.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eInspect fittings for leaks:\u003c\/strong\u003e Use correct sealing methods on the threaded port and test after installation.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\r\n\r\n  \u003c!-- Pro Tip --\u003e\r\n  \u003cdiv class=\"tip-products\"\u003e\r\n    \u003ch4\u003ePro Tip\u003c\/h4\u003e\r\n    \u003cul\u003e\r\n      \u003cli\u003e\r\n        If you’re replacing a pressure switch due to erratic cycling, also inspect for air leaks and check the non-return valve\/unloader line (where fitted). A small leak can mimic switch problems and cause rapid cycling.\r\n      \u003c\/li\u003e\r\n    \u003c\/ul\u003e\r\n  \u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSafety\u003c\/h2\u003e  \u003c!-- Safety TAB --\u003e\r\n  \u003ch4\u003eSafety\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003eIsolate and disconnect \u003cstrong\u003epower\u003c\/strong\u003e before opening any electrical housing or replacing switches.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eDepressurise\u003c\/strong\u003e the compressor\/tank fully before removing the old pressure switch.\u003c\/li\u003e\r\n    \u003cli\u003eWear \u003cstrong\u003eeye protection\u003c\/strong\u003e when working around pressurised fittings and during leak testing.\u003c\/li\u003e\r\n    \u003cli\u003eEnsure wiring is correctly connected and insulated—incorrect wiring can cause damage or unsafe operation.\u003c\/li\u003e\r\n    \u003cli\u003eAfter installation, run a controlled test and confirm the compressor stops at the correct pressure and that there are \u003cstrong\u003eno leaks\u003c\/strong\u003e.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\u003c\/section\u003e","brand":"Saddle Creek","offers":[{"title":"Default Title","offer_id":67500872335650,"sku":"SG COMP06-31","price":216.2,"currency_code":"ZAR","in_stock":false}],"url":"https:\/\/saddlecreek.co.za\/products\/preassure-switch","provider":"Saddle Creek","version":"1.0","type":"link"}