{"product_id":"repl-fuse-only-250v-for-magbase-drills","title":"Repl. Fuse Only 250v For Magbase Drills","description":"\u003c!-- Description --\u003e\r\n\u003ch3\u003eTork Craft Repl. Fuse Only 250V For Magbase Drills (TCMD1000)\u003c\/h3\u003e\r\n\u003cp class=\"feature_box\"\u003e\u003cstrong\u003eAt a Glance: \u003c\/strong\u003eReplacement fuse only, rated 250V, for Tork Craft mag base drills.\u003c\/p\u003e\r\n\r\n\u003cp itemprop=\"description\"\u003e\r\nA fuse is the drill’s built-in “safety sacrifice”—it blows to protect the more expensive components when something goes wrong. If your mag base drill suddenly won’t power up after an overload, a jam, or an electrical surge, the fuse is one of the first things to check. The Tork Craft TCMD1000 Replacement Fuse (250V) is a direct replacement fuse only, designed for mag base drills where a 250V fuse is specified, helping restore proper circuit protection and safe operation once the underlying fault has been resolved.\r\n\u003c\/p\u003e\r\n\r\n\u003cdiv class=\"definition-products\"\u003e\r\n  \u003cstrong\u003eEssential Electrical Protection For Mag Base Drill Reliability\u003c\/strong\u003e\r\n  \u003cp\u003e\r\n  Ideal for maintenance and repair when the original fuse has blown or is damaged. Correct fuse protection helps prevent wiring, switches and control components from suffering costly overload damage.\r\n  \u003c\/p\u003e\r\n\u003c\/div\u003e\u003csection\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003c!-- Features and Benefits --\u003e\r\n\u003ch4\u003eFeatures\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003e250V rated replacement fuse\u003c\/strong\u003e Designed for mag base drill electrical protection where a 250V fuse is required.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFuse only\u003c\/strong\u003e A simple, service-ready replacement component to minimise downtime.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eOvercurrent protection role\u003c\/strong\u003e Helps safeguard electrical components from overload conditions.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch4\u003eBenefits\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eHelps restore operation safely: \u003c\/strong\u003eReplacing a blown fuse can bring the tool back to life with correct protection in place.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eProtects expensive components: \u003c\/strong\u003eA correctly specified fuse helps reduce the risk of damage to control and motor circuits.\u003c\/li\u003e\r\n  \u003cli\u003e\n\u003cstrong\u003eFast, practical repair item: \u003c\/strong\u003eSmall part, big impact—ideal to keep as a spare for workshop readiness.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003c!-- Specifications TAB --\u003e\r\n\u003ch4\u003eSpecifications\u003c\/h4\u003e\r\n\u003ctable class=\"table SpecsTable\"\u003e\r\n  \u003cthead\u003e\r\n    \u003ctr\u003e\r\n      \u003cth class=\"SpecsSubHeading\"\u003eDescription\u003c\/th\u003e\r\n      \u003cth class=\"SpecsSubHeading\"\u003eSpec\u003c\/th\u003e\r\n    \u003c\/tr\u003e\r\n  \u003c\/thead\u003e\r\n  \u003ctbody\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eTork Craft\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eCat No.\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eTCMD1000\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eSpare Part (Fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eComponent\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eReplacement Fuse Only\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003e250V\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eApplication\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eMag Base Drills (As Specified)\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eNotes\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eMatch correct fuse type and rating for your drill model\u003c\/td\u003e\n\u003c\/tr\u003e\r\n  \u003c\/tbody\u003e\r\n\u003c\/table\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eExtra Info\u003c\/h2\u003e\n\u003c!-- Extra Information TAB --\u003e\r\n\u003ch4\u003eExtra Information\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003eSuitable for mag base drills where a \u003cstrong\u003e250V fuse\u003c\/strong\u003e is specified—always match the correct fuse type and rating for your model.\u003c\/li\u003e\r\n  \u003cli\u003eIf the replacement fuse blows again, stop and investigate the cause (overload, damaged wiring, moisture ingress, faulty switch\/control board or motor issues).\u003c\/li\u003e\r\n  \u003cli\u003eCheck the fuse holder for heat damage or looseness—poor contact can cause overheating and repeated failures.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003c!-- Pro Tip --\u003e\r\n\u003cdiv class=\"tip-products\"\u003e\r\n  \u003ch4\u003ePro Tip\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003eNever “upgrade” a fuse rating to stop it blowing. A fuse that doesn’t blow when it should is basically an invitation to expensive smoke.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\r\n\u003c\/div\u003e\r\n\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSafety\u003c\/h2\u003e\n\u003c!-- Safety TAB --\u003e\r\n\u003ch4\u003eSafety\u003c\/h4\u003e\r\n\u003cul\u003e\r\n  \u003cli\u003eDisconnect the tool from the power supply before replacing a fuse or opening electrical covers.\u003c\/li\u003e\r\n  \u003cli\u003eNever bypass a fuse or fit an incorrect rating—this can cause severe damage, fire risk, and injury.\u003c\/li\u003e\r\n  \u003cli\u003eReplace only with the correct fuse type specified for your model (size\/type and rating must match).\u003c\/li\u003e\r\n  \u003cli\u003eAfter replacement, test the drill cautiously at no load first and monitor for abnormal behaviour.\u003c\/li\u003e\r\n\u003c\/ul\u003e\u003c\/section\u003e","brand":"Saddle Creek","offers":[{"title":"Default Title","offer_id":67530437067042,"sku":"TCMD1000","price":6.1,"currency_code":"ZAR","in_stock":false}],"url":"https:\/\/saddlecreek.co.za\/products\/repl-fuse-only-250v-for-magbase-drills","provider":"Saddle Creek","version":"1.0","type":"link"}