{"product_id":"solenoid-valve-for-comp-05-06-07","title":"Solenoid Valve For Comp 05 06 \u0026 07","description":"\u003c!-- Description --\u003e\r\n  \u003ch3\u003eAirCraft Solenoid Valve SG-COMPSP-12 For Comp 05, Comp06 And Comp07\u003c\/h3\u003e\r\n  \u003cp class=\"feature_box\"\u003e\u003cstrong\u003eAt a Glance: \u003c\/strong\u003eElectrically actuated replacement solenoid valve with pre-wired leads for AirCraft Comp 05\/Comp06\/Comp07.\u003c\/p\u003e\r\n  \u003cp itemprop=\"description\"\u003e\r\n    The AirCraft \u003cstrong\u003eSG-COMPSP-12 Solenoid Valve\u003c\/strong\u003e is an electrically controlled air valve used on the AirCraft \u003cstrong\u003eComp 05\u003c\/strong\u003e, \u003cstrong\u003eComp06\u003c\/strong\u003e and \u003cstrong\u003eComp07\u003c\/strong\u003e mini compressor range.\r\n    A solenoid valve opens and closes an internal air passage when it receives an electrical signal—helping manage airflow, automation functions, and correct system behaviour during operation.\r\n    If your compressor is acting up with inconsistent air control, delayed operation, or you suspect a valve is not opening\/closing cleanly, replacing the solenoid valve with the correct AirCraft part is often the quickest route back to smooth, predictable performance.\r\n  \u003c\/p\u003e\r\n\r\n  \u003cdiv class=\"definition-products\"\u003e\r\n    \u003cstrong\u003eReliable Air Control for Mini Compressors: the SG-COMPSP-12 Solenoid Valve\u003c\/strong\u003e\r\n    \u003cp\u003e\r\n      This valve is designed as a service replacement component for compatible AirCraft mini compressor assemblies.\r\n      Match the \u003cstrong\u003eCat No. SG-COMPSP-12\u003c\/strong\u003e to ensure correct fitment for Comp 05, Comp06 and Comp07.\r\n    \u003c\/p\u003e\r\n  \u003c\/div\u003e\u003csection\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e  \u003c!-- Features and Benefits --\u003e\r\n  \u003ch4\u003eFeatures\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eElectrically actuated valve\u003c\/strong\u003e Opens\/closes airflow in response to an electrical signal.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eCompatible with Comp 05\/Comp06\/Comp07\u003c\/strong\u003e Part-number referenced fitment for these mini compressors.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003ePre-wired leads\u003c\/strong\u003e Simplifies installation and keeps wiring tidy.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eThreaded connection\u003c\/strong\u003e Designed to mount into the correct port\/fitting on the compressor assembly.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\r\n\r\n  \u003ch4\u003eBenefits\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eRestores correct airflow control: \u003c\/strong\u003eHelps fix inconsistent operation caused by a sticking or faulty valve.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eImproves reliability: \u003c\/strong\u003eCleaner switching and control supports predictable compressor behaviour.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eReduces downtime: \u003c\/strong\u003eQuick replacement part when matched by part number.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eHelps prevent air loss: \u003c\/strong\u003eA properly sealing valve reduces leakage and pressure drop (system dependent).\u003c\/li\u003e\r\n  \u003c\/ul\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e  \u003c!-- Specifications TAB --\u003e\r\n  \u003ch4\u003eSpecifications\u003c\/h4\u003e\r\n  \u003ctable class=\"table SpecsTable\"\u003e\r\n    \u003cthead\u003e\r\n      \u003ctr\u003e\r\n        \u003cth class=\"SpecsSubHeading\"\u003eDescription\u003c\/th\u003e\r\n        \u003cth class=\"SpecsSubHeading\"\u003eSpec\u003c\/th\u003e\r\n      \u003c\/tr\u003e\r\n    \u003c\/thead\u003e\r\n    \u003ctbody\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eBrand\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eAirCraft\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eCat No.\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eSG-COMPSP-12\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eSolenoid Valve (Spare Part)\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eCompatible With\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eAirCraft Comp 05, Comp06 and Comp07\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eFunction\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eElectrical on\/off control of airflow\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eThreaded port connection (confirm size to existing valve)\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eWiring\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003ePre-wired leads (as pictured)\u003c\/td\u003e\n\u003c\/tr\u003e\r\n      \u003ctr\u003e\n\u003ctd class=\"SpecLeft\"\u003eReplacement Use\u003c\/td\u003e\n\u003ctd class=\"SpecRight\"\u003eDirect replacement by part number\u003c\/td\u003e\n\u003c\/tr\u003e\r\n    \u003c\/tbody\u003e\r\n  \u003c\/table\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eExtra Info\u003c\/h2\u003e  \u003c!-- Extra Information TAB --\u003e\r\n  \u003ch4\u003eExtra Information\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Intended for AirCraft \u003cstrong\u003eComp 05\u003c\/strong\u003e, \u003cstrong\u003eComp06\u003c\/strong\u003e and \u003cstrong\u003eComp07\u003c\/strong\u003e.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eVerify electrical requirements:\u003c\/strong\u003e Confirm the correct coil voltage and wiring configuration for your unit.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eCheck fittings:\u003c\/strong\u003e Confirm thread type\/size matches your existing solenoid valve connection.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eLeak test:\u003c\/strong\u003e After installation, pressurise and check joints with soapy water for a proper seal.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\r\n\r\n  \u003c!-- Pro Tip --\u003e\r\n  \u003cdiv class=\"tip-products\"\u003e\r\n    \u003ch4\u003ePro Tip\u003c\/h4\u003e\r\n    \u003cul\u003e\r\n      \u003cli\u003e\r\n        If the old solenoid failed due to contamination, check for moisture or debris in the air path and ensure filters\/dryers (if fitted) are working. Clean air dramatically improves valve lifespan.\r\n      \u003c\/li\u003e\r\n    \u003c\/ul\u003e\r\n  \u003c\/div\u003e\u003c\/section\u003e\u003csection\u003e\u003ch2\u003eSafety\u003c\/h2\u003e  \u003c!-- Safety TAB --\u003e\r\n  \u003ch4\u003eSafety\u003c\/h4\u003e\r\n  \u003cul\u003e\r\n    \u003cli\u003eIsolate and disconnect \u003cstrong\u003epower\u003c\/strong\u003e (and remove battery if applicable) before replacing the solenoid valve.\u003c\/li\u003e\r\n    \u003cli\u003e\n\u003cstrong\u003eDepressurise\u003c\/strong\u003e the system fully before loosening fittings or removing the old valve.\u003c\/li\u003e\r\n    \u003cli\u003eWear \u003cstrong\u003eeye protection\u003c\/strong\u003e when working with pressurised fittings and during leak testing.\u003c\/li\u003e\r\n    \u003cli\u003eEnsure wiring is correctly connected and insulated before powering up.\u003c\/li\u003e\r\n    \u003cli\u003eAfter installation, perform a controlled test run and confirm correct operation with no leaks.\u003c\/li\u003e\r\n  \u003c\/ul\u003e\u003c\/section\u003e","brand":"Saddle Creek","offers":[{"title":"Default Title","offer_id":67500874957090,"sku":"SG COMPSP-12","price":570.4,"currency_code":"ZAR","in_stock":false}],"url":"https:\/\/saddlecreek.co.za\/products\/solenoid-valve-for-comp-05-06-07","provider":"Saddle Creek","version":"1.0","type":"link"}